Specification:

Model   CS6L-1017  CS6L-1026  CS6L-1035
Control System
 BNT-790F
Regeneration Type
 Down Flow
Regeneration Mode
 Days, Calendar Weekday, Meter Immediate, Meter Delay, Meter Override
Hardness Removal
(Gram)
(@ 48 g/L salt dosage)
 
401
577
801 
(@ 96 g/L salt dosage)
 630
907
1259
(@ 160 g/L salt dosage)
758
1092
1517
Tank Size
10x17
10x26
10x35
Resin Quantity
12.5 L
18 L
25 L
Salt Storage Capacity
23 Kg
41 Kg
61 Kg
Rated Service Flow Rate
17 L/M
24 L/M
33 L/M
Back Wash Flow Rate
9 L/M
Water Used Per Regeneration
(@ 96 g/L salt dosage)
58 L
92 L
127 L
Product Dimension(D×W×H mm)
470x330x660
470x330x870
470x330x1100
Carton Size(mm)
520x360x740
520x360x950
520x360x1170
Shipping Weight
22 Kg
31 Kg
39 Kg
Container Capacity(40" HQ)
414 pcs
276 pcs
276 pcs
Plumbing Connections
3/4” or 1” Fittings Available
Electrical Requirements
Input 110V-120V / 220-240V AC 50/60 Hz 
Output 12V AC 650mA
Water Supply
Municipal
Operating Temperature
4~43 ℃
Operating Pressure
0.21~0.86 Mpa

Notes: The data of softener performance is only for reference, it may vary from different water qualities and applications.